C H A P T E R 2 : I P C O N F I G U R A T I O N

6Click the “Save Settings” button to store the configuration changes to the HS500E’s non-volatile flash memory.

7Manually cycle power to the HS500E. It takes 15 – 30 seconds for the HS500E to reboot, at which time your IP configuration changes will be implemented.

8After the HS500E has completely restarted, verify the new IP configuration by opening a Web browser and entering the newly assigned IP address in the URL field.

2.3PINGING THE HS500E

After the HS500E has restarted, go to the PC and run PING.EXE (from Microsoft Windows systems) or use another network diagnostic tool that can run a similar TCP/IP ping command. Using a Ping utility helps verify that the HS500E is accessible across the network.

To Ping the HS500E from the PC, open a command prompt and at the C:\> prompt type:

Ping (IP Address)

(Where “IP Address” is the new IP address assigned to the HS500E).

If the HS500E is online and functioning, a successful response will be similar to:

Reply from (IP Address): bytes=32 time=3ms TTL=60

Reply from (IP Address): bytes=32 time=1ms TTL=60

Reply from (IP Address): bytes=32 time=1ms TTL=60

Reply from (IP Address): bytes=32 time=1ms TTL=60

If the PC does not receive a successful response from the HS500E, it may indicate an improperly configured IP address setting. Please verify that you followed the instructions above for setting the IP address of the HS500E.

Also, be sure to disable any firewall services running on the PC. Firewalls can potentially block communications between the PC, the PLC and/or the HS500E.

H S 5 0 0 E – O P E R A T O R ’ S M A N U A L

P / N : 1 7 - 1 3 0 5 R E V 0 2 ( 1 2 - 0 5 )

 

P A G E 2 0 O F 8 2