Emsa HS500E manual M m a n d P a c k e t S t r u c t u r e Ta b l e, 06 +, Seconds

Models: HS500E

1 82
Download 82 pages 58.18 Kb
Page 22
Image 22

C H A P T E R 3 : R F I D C O M M A N D S

3 . 1 . 1

C o m m a n d P a c k e t S t r u c t u r e Ta b l e

 

 

W o r d

 

M S B

 

L S B

 

D e s c r i p t i o n

 

 

 

#

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01

 

00

06 (+

 

OVERALL LENGTH:

 

 

 

 

 

 

number of

 

The first word in a command packet is the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

additional

 

 

 

 

 

 

 

 

 

Overall Length. This 2-byte value indicates the

 

 

 

 

 

 

 

data

 

 

 

 

 

 

 

 

 

total number of words in the command (including

 

 

 

 

 

 

 

words, if

 

 

 

 

 

 

 

 

 

this - the Overall Length field). This value will

 

 

 

 

 

 

 

any)

 

 

 

 

 

 

 

 

 

always be at least six words (0x0006).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

02

 

AB

03

 

COMMAND ID:

 

 

 

 

 

 

 

 

 

The second word contains the Command ID. For

 

 

 

 

 

 

 

 

 

example: Write Data Command = 0xAB03

 

 

 

 

 

 

 

 

 

See the Section 3.2.1 - RFID Command Table for

 

 

 

 

 

 

 

 

 

a complete list.

 

 

 

 

 

 

 

 

 

 

 

 

03

 

00

01

 

NODE ID:

 

 

 

 

 

 

 

 

The third word contains the Node ID of the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

antenna / controller for which the command is

 

 

 

 

 

 

 

 

 

directed. This value should always be 0x0001 for

 

 

 

 

 

 

 

 

 

the HS500E.

 

 

 

04

 

00

32

 

TIMEOUT VALUE:

 

 

 

 

 

 

 

 

Word four in a command packet contains the 2-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

byte Timeout Value. This value sets the

 

 

 

 

 

 

 

 

 

maximum length of time for which the HS500E

 

 

 

 

 

 

 

 

 

will attempt to complete the given command. This

 

 

 

 

 

 

 

 

 

time limit” is measured in 1/10th (.10) second

 

 

 

 

 

 

 

 

 

increments, where 0x0032 = 50 x .10 = 5

 

 

 

 

 

 

 

 

 

seconds.

 

 

 

05

 

00

01

 

START ADDRESS:

 

 

 

 

 

 

 

 

The fifth word, Start Address, indicates the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

location of tag memory where a read or write

 

 

 

 

 

 

 

 

 

operation will begin (when applicable).

 

 

 

06

 

00

01

 

READ/WRITE LENGTH:

 

 

 

 

 

 

 

 

The Read/Write Length is the sixth word (when

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

applicable) and represents the number of bytes

 

 

 

 

 

 

 

 

 

that are to be retrieved from or written to the

 

 

 

 

 

 

 

 

 

RFID tag.

 

 

 

 

 

 

 

 

 

 

 

H S 5 0 0 E – O P E R A T O R ’ S M A N U A L

P / N : 1 7 - 1 3 0 5 R E V 0 2 ( 1 2 - 0 5 )

 

P A G E 2 2 O F 8 2

Page 22
Image 22
Emsa HS500E M m a n d P a c k e t S t r u c t u r e Ta b l e, 06 +, See the .2.1 Rfid Command Table for Complete list