Emsa HS500E manual D e m a n d O b j e c t 0 x 6 7 1 0 I n s ta n c e s, Only

Models: HS500E

1 82
Download 82 pages 58.18 Kb
Page 79
Image 79

A P P E N D I X C : E T H E R N E T / I P – O B J E C T M O D E L

C . 2 3

O n D e m a n d O b j e c t ( 0 x 6 7 - 1 0 I n s ta n c e s )

Class Attributes (Instance 0)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Attribute

Name

 

Data Type

Default

 

Access

ID

 

 

 

 

 

 

Data

 

Rule

 

 

 

 

 

 

 

Value

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Revision

 

UINT

 

 

1

 

 

Get

 

 

 

 

 

 

 

 

 

 

Instance Attributes (Instances 1-32)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Attribute

Name

Data Type

 

Default

 

Access

ID

 

 

 

 

 

Data Value

 

Rule

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Instance Type (0-3)

USINT

0

 

 

Get

 

0

- Disable

 

 

 

 

 

 

 

 

 

1

– ControlLogix

 

 

 

 

 

 

 

 

 

2

– SLC 5/05

 

 

 

 

 

 

 

 

 

3

– PLC5E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

PLC IP Address

UDINT

0

 

 

Get

 

 

 

 

 

 

 

3

PLC Slot Location (0-255)

USINT

0

 

 

Get

 

 

 

 

 

 

 

11

Max Write Size in Words

UINT

0

 

 

Get

 

0

– Disabled

 

 

 

 

 

 

 

 

 

1

– 100 Words

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

Write Tag Name (ControlLogix

SHORT

0

 

 

Get

 

Only)

STRING

 

 

 

 

 

 

 

 

 

 

 

 

 

13

Write File Number (SLC/PLC

UINT

7

 

 

Get

 

Only)

 

 

 

 

 

 

 

 

 

NX:0 where X is the File

 

 

 

 

 

 

 

 

 

Number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H S 5 0 0 E – O P E R A T O R ’ S M A N U A L

P / N : 1 7 - 1 3 0 5 R E V 0 2 ( 1 2 - 0 5 )

 

P A G E 7 9 O F 8 2

Page 79
Image 79
Emsa HS500E manual D e m a n d O b j e c t 0 x 6 7 1 0 I n s ta n c e s, Only