Emsa HS500E manual S E T B a T T E R Y C O U N T E R, There is no response for this command

Models: HS500E

1 82
Download 82 pages 58.18 Kb
Page 37
Image 37

C H A P T E R 3 : R F I D C O M M A N D S

C O M M A N D F 4 :

R E S E T B A T T E R Y C O U N T E R

D E S C R I P T I O N

Command F4 resets the value of a tag’s Battery Counter to zero (0x00). This command is intended to be used when replacing the batteries in an active RFID tag and will reset the value of the Battery Counter to zero (0x00).

Located at tag address 0x0000, the Battery Counter stores a one-byte value that indicates the number of operating hours that the tag has been in use since it has last had its internal batteries replaced. A tag should have its batteries replaced after it has accumulated 15 hours of use. When this value reaches 0x0F, battery life is in a condition of decay and should be replaced.

To retrieve the Battery Counter Value, execute Command 02 and note the value stored at address 0x0000 on the tag. Reading address ZERO on the tag should only be performed by one station in a typical assembly line.

E X A M P L E

Command F4: Reset Battery Counter Value – Command Structure

Field Name

MSB

LSB

Overall Length

00

06

 

 

 

MSB = Command ID (0xF4)

F4

00

LSB = 0x00 for this command.

 

 

 

 

 

MSB = 0x00

00

01

LSB = Node ID #: (0x01)

 

 

 

 

 

Timeout Value*

00

00

 

 

 

Start Address*

00

00

 

 

 

Read/Write Length*

00

00

 

 

 

Word Value

0006

F400

0001

0000

0000

0000

*Not applicable for this command, set values to zero (0x00). This command uses a hard coded Timeout Value of 2 seconds.

R E S P O N S E F R O M H S 5 0 0 E

There is no response for this command.

R E S E T B A T T E R Y C O U N T E R E R R O R

The Reset Battery Counter command may appear to time-out or generate an error. After executing Command F4, the user should execute Command 02 and check the data at tag address 0x0000 to confirm that the value of the Battery Counter was indeed reset to 0x00.

H S 5 0 0 E – O P E R A T O R ’ S M A N U A L

P / N : 1 7 - 1 3 0 5 R E V 0 2 ( 1 2 - 0 5 )

 

P A G E 3 7 O F 8 2

Page 37
Image 37
Emsa HS500E manual S E T B a T T E R Y C O U N T E R, There is no response for this command