C H A P T E R 3 : R F I D C O M M A N D S

C O M M A N D F 1 :

T E S T L E D S / G E T I N F O

D E S C R I P T I O N

Command F1 tests the HS500E’s LEDs and retrieves the unit’s currently installed software version number. This command causes the HS500E’s LEDs to flash a coded diagnostic pattern while also retrieving the version number of the installed software.

E X A M P L E

In this example the LEDs on the HS500E will be tested and its software version number will be retrieved. Timeout Value, Start Address and Read/Write Length parameters are not applicable for this command (all values for these fields should be set to 0x00).

Command F1: Test LEDs / Get Info – Command Structure

Field Name

MSB

LSB

Overall Length

00

06

 

 

 

Command ID Number: 0xF1 + [0x00]

F1

00

 

 

 

MSB = 0x00

00

01

LSB = Node ID # (always 0x01)

 

 

 

 

 

Timeout Value

00

00

 

 

 

Start Address

00

00

 

 

 

Read/Write Length

00

00

 

 

 

Word Value

0006

F100

0001

0000

0000

0000

H S 5 0 0 E – O P E R A T O R ’ S M A N U A L

P / N : 1 7 - 1 3 0 5 R E V 0 2 ( 1 2 - 0 5 )

 

P A G E 3 1 O F 8 2

Page 31
Image 31
Emsa HS500E manual M M a N D F S T L E D S / G E T I N F O, 0006 F100 0001 0000