C H A P T E R 3 : R F I D C O M M A N D S

C O M M A N D F 3 :

W R I T E I P A D D R E S S

D E S C R I P T I O N

Command F3 is used to modify and store the IP address of the HS500E.

NOTE: The unit’s IP address can also be changed using the built-in HTML Server. See Chapter 2 for instructions.

Follow the steps below to configure the unit’s IP address.

S E T T I N G T H E I P A D D R E S S O F T H E H S 5 0 0 E

1. Run Command F3 as shown below, (the R/W LED on the HS500E will blink repeatedly for 15 - 20 seconds).

2. After blinking stops, cycle power to the unit (the R/W LED will again blink for 15 -20 seconds).

3. After the R/W LED has stopped blinking (the second time) configure your Host application to connect to the new IP address assigned to the HS500E in step 1.

E X A M P L E

This example sets the IP address of the HS500E to 192.168.253.115.

Command F3: Write IP Address – Command Structure

Field Name

MSB

LSB

Word Value

Overall Length

00

06

0006

 

 

 

 

MSB = Command ID (0xF3)

F3

00

F300

LSB = 0x00 for this

 

 

 

command.

 

 

 

 

 

 

 

IP Address (first octet)

0x00 (always)

C0 (192 decimal)

00C0

 

 

 

 

IP Address (second octet)

0x00 (always)

A8 (168 decimal)

00A8

 

 

 

 

IP Address (third octet)

0x00 (always)

FD (253 decimal)

00FD

 

 

 

 

IP Address (fourth octet)

0x00 (always)

73 (115 decimal)

0073

 

 

 

 

H S 5 0 0 E – O P E R A T O R ’ S M A N U A L

P / N : 1 7 - 1 3 0 5 R E V 0 2 ( 1 2 - 0 5 )

 

P A G E 3 5 O F 8 2

Page 35
Image 35
Emsa manual I T E I P a D D R E S S, This example sets the IP address of the HS500E to