C H A P T E R 3 : R F I D C O M M A N D S

Command 02: Read Data – Response Structure

Field Name

MSB

LSB

Word Value

Overall Length (in words)

00

08

0008

 

 

 

 

MSB =RF Error Counter

00

02

0002

LSB = Command ID Echo

 

 

 

 

 

 

 

MSB = Instance Counter

01

01

0101

LSB = Node ID Echo

 

 

 

 

 

 

 

RF Time

RFT1

RFT2

XXXX

 

 

 

 

MSB = RF Retry Counter

01

00

0100

LSB = Reserved

 

 

 

 

 

 

 

Total Time

TT

TT

TTTT

 

 

 

 

Returned Data (bytes 1, 2)

D1

D2

DATA

 

 

 

 

Returned Data (bytes 3,4)

D3

D4

DATA

 

 

 

 

H S 5 0 0 E – O P E R A T O R ’ S M A N U A L

P / N : 1 7 - 1 3 0 5 R E V 0 2 ( 1 2 - 0 5 )

 

P A G E 2 7 O F 8 2

Page 27
Image 27
Emsa HS500E manual MSB = RF Retry Counter 0100 LSB = Reserved Total Time, Returned Data bytes 1, Returned Data bytes 3,4