RoamAbout Access Point 3000 Hardware Installation Guide 3-1
3
Initial Configuration

Overview

TheEnterasysNetworksRoamAboutAccessPoint3000includesaWebbasedinterface,anda
directconnectiontotheconsoleportforCLImanagement.YoucanalsomanagetheAccessPoint
3000usinganSNMPmanager,suchasEnterasysNetworksNetSightAtlas.
YoucanperformtheinitialconfigurationstepsthroughtheCLIortheWeb interface.
TheaccesspointrequestsanIPaddressfromaDynamicHostConfigurationProtocol(DHCP)
serverbydefault.IfaDHCPserverdoesnotrespond,thentheaccesspointusesthedefault
address,192.168.1.1.
IfyouutilizeaDHCPservertoprovisionnewelementsinyourIPnetwork,useyourDHCPserver
orotherutilitiestodeterminetheIPaddressassignedtothisaccesspoint.Then,usetheDHCP
assignedIPaddresstoconnecttotheaccesspoint.

Using the CLI

TheAccessPoint3000includesanRS232serialportthatenablesaconnectiontoaPCorterminal
formonitoringandconfiguration.AttachaVT100compatibleterminal,oraPCrunninga
terminalemulationprogramtotheaccesspoint.Youcanusetheconsolecableprovidedwiththis
package,oruseanullmodemcablethatcomplieswiththewiringassignmentsshownin
Appendix C.

Required Connections

Toconnecttotheconsoleport,completethefollowingsteps:
1. Connecttheconsolecabletotheserialportonaterminal,oraPCrunningterminalemulation
software,andtightenthecaptiveretainingscrewsontheDB9connector.
2. ConnecttheotherendofthecabletotheRS232serialportontheaccesspoint.
3. Makesuretheterminalemulationsoftwareissetasfollows:
Selecttheappropriateserialport(COMport1or2).
Setthedatarateto9600baud.
Setthedataformatto8databits,1stopbit,andnoparity.
Setflowcontroltonone.
SettheemulationmodetoVT100.