Connecting to the Network

Connecting to the Network

This section provides the procedures for connecting unshielded twisted pair (UTP) segments from the network or other devices to the 7H4385‐49 (“Connecting UTP Cables to 7H4385‐49” on page 3‐15).

Note: If the DFE module is being installed in a network using Link Aggregation, there are rules concerning the network cable and port configurations that must be followed for Link Aggregation to operate properly. Before connecting the cables, refer to the Enterasys Matrix DFE-Platinum Series Configuration Guide for the configuration information. For details on how to obtain manuals, refer to the “Related Documents” in About This Guide.

Connecting UTP Cables to 7H4385-49

The fixed RJ45 front panel connections of the 7H4385‐49 are 10/100 Mbps ports. These ports have internal crossovers, and support automatic‐polarity sensing when configured for automatic‐negotiation.

If automatic‐negotiation is not activated on a port, use a straight‐through cable when connecting a workstation to the port. When connecting a networking device to the port, such as a bridge, repeater, or router, use a crossover cable.

If a port is set for auto‐negotiation, automatic‐polarity sensing is also activated. Automatic‐polarity sensing eliminates the need for a crossover cable, regardless if the connection is to another network device or a workstation.

Note: All RJ45 front panel ports on the 7H4385-49 support Category 5 Unshielded Twisted Pair (UTP) cabling with an impedance between 85 and 111 ohms. Category 3 cable may be used if the connection is going to be used only for 10 Mbps.

The RJ45 fixed front panel connectors of the 7H4385‐49 also support PoE‐compliant connections to PDs (powered devices) that require 48 Vdc through the UTP cable to operate. Whether the 48 Vdc is available through the backplane of an N5 chassis or externally from an N‐POE Power System, you can verify if there is power at each port as described later in this procedure.

DFE-Platinum Series Hardware Installation Guide 3-15