EPSON Perfection 610 | Revision B |
3.1 Overview
This chapter describes troubleshooting procedures for this scanner.
3.2 Self-Diagnostic Function
The
Table 3-1. Errors Detected by the Self-Diagnostic Function
Lamp Condition |
|
| Error Type (Cause Remedy) |
|
|
| |
No effect |
| Command Error | |
|
| Cause: | Undefined command |
|
| Disposition: The scanner ignores the wrong command and | |
|
|
| parameters, and returns NACK and waits for the |
|
|
| next command and parameters. |
|
| Remedy: | The scanner clears the error when it receives a |
|
|
| correct command and parameters. |
|
|
| |
Blinking |
| Communication Error | |
(Goes off after 30 |
| Cause: | Wrong communication procedure is detected. |
minutes.) |
|
| USB is disconnected during communication. |
|
|
| |
|
| Disposition: The scanner turns the lamp off and stops | |
|
|
| operating. |
|
| Remedy: | Turn the scanner off and back on. |
|
|
| Disconnect the USB cable and then connect it |
|
|
| properly. |
|
| Acceptable command: None | |
|
|
|
|
Off |
| Fatal Error |
|
(=the lamp has |
| Cause: | The lamp has blown out. |
blown out.) |
|
| The scanner is turned on or receives a |
|
|
| command with the transportation screw |
Blinking |
|
| locked. |
(=error except the |
|
| The scanner is broken. |
lamp has blown |
| Disposition: The scanner turns the lamp off and stops | |
out.) |
|
| operating. |
|
| Remedy: | After removing the cause of the problem, |
|
|
| Turn the scanner off and back on. |
|
|
| Send a ESC@ command. |
|
|
| Disconnect the USB cable and connect it |
|
|
| again. |
|
| Acceptable command: [ESC F, ESC f, ESC @] | |
|
|
|
|
Troubleshooting | Overview | 22 |