Epson 610 manual Carriage Motor / Timing Belt Removal, Shield Plate Removal

Models: 610

1 52
Download 52 pages 60.27 Kb
Page 36
Image 36

EPSON Perfection 610

Revision B

4.2.6 Carriage Motor / Timing Belt Removal

1.Release the Carriage Lock. (See Section 4.2.1.)

2.Remove the Document Cover. (See Section 4.2.2.)

3.Remove the Upper Housing. (See Section 4.2.3.)

4.Remove the Carriage Unit. (See Section 4.2.5.)

5.Remove the two screws (CBS, M3x4) securing the FFC fixing plate, and then remove the FFC fixing plate.

6.Remove the three screws (gold, CBS, M3x4/M3x6) and the two hooks at the rear edge, and then remove the main board cover.

7.Remove the two screws (gold, CBS, M3x4) securing the CR Motor Unit, and then shift the CR Motor Unit inward.

8.Disconnect the cable for the CR Motor Unit from the connector on the main board, and then remove the CR Motor Unit.

6. Hooks

5. FFC Fixing Plate

6.CBS Screws M3x6)

6.Main Board Cover

6. CBS Screw (M3x4)

5. CBS Screws (M3x4)

 

Figure 4-21. Shield Plate Removal

CR Motor Unit

Connector

CBS Screws (M3x4)

Figure 4-22. CR Motor Unit Removal (1)

Figure 4-23. CR Motor Unit Removal (2)

Assembly and Disassembly

Disassembly Procedures

36

Page 36
Image 36
Epson 610 manual Carriage Motor / Timing Belt Removal, Shield Plate Removal