6.1 Overview

This chapter provides information necessary to keep the scanner function in optimum condition constantly and to prevent troubles.

6.1.1 Cleaning

Perform cleaning when stain is noticeable. Stain on the document glass, particularly, has a direct effect on scanned images. Therefore, be sure to clean ￿the glass well to remove stain thoroughly.

Never apply any organic solvents such as thinner or

C A U T I O N

benzene, since these may deteriorate plastic and rubber parts.

Outer Cases

Wipe dirt off with a clean cloth, moistened with water and squeezed tightly.

￿To remove severe stains, use a neutral detergent.

Document Glass

Remove dust and paper debris with a dry, clean cloth. If the dirt is severe or foreign matter is stuck on the glass, use a cloth soaked with neutral detergent. If any trace is left, wipe it off with a dry, clean cloth again.

6.1.2 Lubrication

You need to lubricate the carriage unit if you have replaced it or notice it making abnormal noise. See the following tables for the recommended grease type and points to apply it.

Table 6-1. Recommended Grease

Grease Type

 

Contents

 

Part Number

 

Availability

 

 

 

 

 

 

 

G-26

 

40g

 

B702600001

 

E *

 

 

 

 

 

 

 

*: EPSON exclusive (Not on the market)

Table 6-2. Lubrication Points

Figure

 

Lubrication Points

 

Lubrication

 

 

 

 

 

 

Table 6-1

 

Transmission gear shaft of the CR motor and

 

G-26

(1x3 mm) for

 

 

drive pulley shaft.

 

each

 

 

 

 

 

 

 

Figure 6-1

 

Driven pulley shaft

 

G-26

(1x3 mm)

 

 

 

 

 

 

Excessive lubrication may cause the carriage

C A U T I O N

mechanism to be damaged or operate abnormally.

G-26

G-26

Figure 6-1. Lubrication Points

Maintenance