EPSON Stylus PHOTO 810/820/830

Revision B

4.3.3 CR unit removal

1.Remove the Upper housing from the printer. (Refer to Section 4.3.1)

2.Release the change lever toward the backside of the printer by using the tweezers, and move the CR unit from the CR home position to around the center position.

3.Loosen the CR timing belt by pushing the Driven pulley holder to the right side, and remove the CR timing belt carefully from the CR motor pinion gear.

.

1

2

CR timing belt

Figure 4-11. CR timing belt removal

4.Remove the Compression spring 19.6 from the Driven pulley holder by using the tweezers.

Driven pulley holder

Compression spring 19.6

Figure 4-12. Compression spring 19.6 removal

5.Slide the Driven pulley holder to the right side, and remove it forward.

6.Release the Head FFC from the Spacer FFC on the LD roller shaft holder, and disconnect the Head FFC from the connectors (CN8, CN9) on the Main board. (Refer to Figure 4-7)

7.Release two CR guide shaft rod springs from the hooks on the left and right side of the Main frame.

Left side

 

Right side

 

 

 

 

 

 

 

 

 

 

 

 

 

CR guide shaft Rod spring

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 4-13. CR guide shaft rod spring release

C H E

† In this step, you cannot remove the left CR guide shaft rod spring

P O I

from the CR guide shaft even if it is released from the Main

frame. So, when sliding the CR guide shaft in the next step,

 

 

remove the left CR guide shaft rod spring carefully.

Disassembly and Assembly

Disassembly

98