Stylus Photo 720

 

 

 

 

 

 

Revision B

 

 

 

 

 

Table 3-3. Error indication and status monitor 3

 

 

 

 

 

 

 

 

 

 

Printer status

 

Indicators

Condition for error detection

Power

 

 

 

Status monitor 3 message

 

 

 

Error

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This error is detected when the ink consumption

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

amount reaches about 90%.

 

 

 

 

[Bk I/C]

 

 

 

[Note]

 

 

 

 

Blink -> Blink

 

 

 

When the ink low condition is detected, Error

Ink low condition

 

On-> Blink

 

 

 

 

 

 

 

 

 

reset LED is blinking. The printer continue to

 

 

 

 

[Col I/C]

 

 

 

keep this LED status even if brand new ink

 

 

 

 

Blink -> Blink2

 

 

 

cartridge is installed at the I/C replacement

 

 

 

 

 

 

 

 

position.

 

 

 

 

 

 

 

 

Then, when the CR unit returns to the home

 

 

 

 

 

 

 

 

position, this LED status is reset (LED is off).

 

 

 

 

 

Note : Even if this error is indicated on the STM3, you can continue the printing

 

 

 

 

 

 

until I/C becomes ink end condition. However, the head cleaning operation

 

 

 

 

 

 

cannot be done so that the remaining ink is low condition.

 

Communication error

 

Off

 

Off

 

 

 

This error is detected when the printer cannot

 

 

 

 

 

communicate with the PC correctly.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

" A -> B " : A is a indicator condition when the CR unit is in the home position.

 

B is a indicator condition in the ink replacement sequence.

 

Blink : On 0.5sec + Off 0.5sec

 

 

 

 

 

 

Blink2 : On 0.2sec + Off 0.2sec + On 0.2sec + Off 0.4sec

 

Troubleshooting

Troubleshooting with LED Error Indications and Status Monitor 3 Message

64