EPSON Stylus PHOTO 810/820/830

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Revision B

 

 

 

Table 3-19. Check point for the poor printing quality

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Occurrence

Detailed phenomenon

Defective

 

 

 

 

Check point

Remedy

 

timing

 

 

 

 

 

unit/part name

 

 

 

 

 

CR position

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. Check if there is any foreign material around the seal

1. Remove the foreign material around the seal

 

 

[Phenomenon 1]

 

rubber parts on the Cap unit.

rubber parts carefully.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

In the CL sequence, the Pump unit seems

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Seal rubber portion

 

 

* The left figure is the cap for Stylus C20.

 

 

to work correctly. But, the ink is not

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The function of the Cap unit is the same

 

 

ejected to the Waste drain ink pad at all.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

although the cap size is different between

 

 

Moreover, any ink is not absorbed from

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stylus C20 and Stylus Photo 810/820.

 

 

the Printhead to the cap.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[Phenomenon 2]

 

2. Check if any damage is observed around the seal rubber

 

 

 

In the CL sequence, the ink is ejected to

 

parts on the Cap unit.

2. Replace the Printer mechanism with new one.

 

 

 

3. Check if the Compression spring is assembled in the Cap

 

 

the Waste drain ink pad (this means the

 

 

 

 

Pump unit & the Cap unit works

 

unit correctly.

3. Replace the Printer mechanism with new one.

 

 

correctly). But, the dot missing is not

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

solved at the specific nozzles even if the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

several CLs are performed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[Phenomenon 3]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation

 

 

 

 

Compression spring

 

 

 

 

In the CL sequence, the ink is ejected to

Cap unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4. Check if the Pump tube is connected to the bottom of the

 

 

-

the Waste drain ink pad (this means the

 

 

 

 

 

 

Pump unit & the Cap unit works

 

Cap unit correctly

 

 

 

correctly). But, the wiping operation is

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4. Replace the Printer mechanism with new one.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

not performed correctly and the colors

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

are mixed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[Phenomenon 4]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

In the CL sequence, the ink is ejected to

 

 

 

 

 

 

Pump tube

 

 

 

 

 

 

 

 

 

 

connection point

 

 

 

 

 

 

the Waste drain ink pad. But, the dot

 

 

 

 

 

 

 

 

 

 

 

5. Check if the Extension spring 0.523 comes off from the

 

 

 

missing occurs on the several nozzle in

 

 

 

 

the printing.

 

Slider cap.

 

 

 

 

 

6. Check if the Extension spring 0.383 comes off from the

5. Reassemble the Extension spring 0.523

 

 

[Phenomenon 5]

 

Slider lock lever.

correctly.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6. Reassemble the Extension spring 0.383

 

 

In the CL sequence, the ink is ejected to

 

 

 

 

 

 

Exp. spring 0.523

 

 

 

the Waste drain ink pad. But, the missing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

correctly.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

point (dot missing nozzle) is changed in

 

 

Exp. spring 0.383

 

 

 

 

 

 

 

 

 

 

every CL operation.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Troubleshooting

Unit Level Troubleshooting

82