EPSON Stylus PHOTO 810/820/830

Revision B

4.3.7 Holder shaft unit removal

1.Remove the Upper housing from the printer. (Refer to Section 4.3.1)

2.Remove the ASF unit from the printer (Refer to Section 4.3.5)

3.Release the Head FFC from the Spacer FFC on the LD roller shaft holder.

LD roller shaft holder

8.Move the Pump unit to the right side slightly while holing the whole of the Holder shaft unit, and pull the bottom of the Holder shaft unit toward the backside of the printer. (Step 3 in the Figure 4-31)

Step2) Pull the Holder shaft unit upward

Holder shaft unit

Spacer FFC

 

 

 

Connector

 

 

 

Figure 4-30. Head FFC removal

4.Disconnect the CR motor connector cable and the HP/PE Sensor cable from the connectors (CN4, CN12) on the Main board.

5.Release the CR motor connector cable from five hooks on the LD roller shaft holder.

6.Release the Change lever toward the backside of the printer by using the tweezers, and move the CR unit to the leftmost side (far side).

7.Push two hooks of the LD roller shaft holder, and pull the Holder shaft unit upward slightly from the Main frame. (Step1, 2 in the Figure 4-31)

Step1) Push two hooks

 

Step3) Move the Pump unit

 

to the right side

 

 

 

 

 

Figure 4-31. LD roller shaft holder removal

9.Remove the LD roller shaft along with the Clutch mechanism from the LD roller shaft holder.

LD roller shaft holder

Clutch mechanism

LD roller

 

 

 

 

Spur gear 35.2

 

LD roller shaft

 

 

 

 

Figure 4-32. LD roller with Clutch mechanism removal

Disassembly and Assembly

Disassembly

107