EPSON Stylus PHOTO 810/820/830

Revision B

Table 7-11. EEPROM Address Map (continued)

Address

Explanation

Setting

QPIT

Factory

setting

setting

 

 

 

 

 

 

 

 

30H

Interface selection

01H : Auto

00H

00H

 

 

02H : Parallel

 

 

 

 

08H : USB

 

 

 

 

Others : Auto

 

 

 

 

 

 

 

31H

Interface time-out

0 to 255

0AH

0AH

 

 

(by second,

 

 

 

 

value of 0 means 10 seconds)

 

 

 

 

 

 

 

32H

I/F Speed

Bit7,6: Reserved

00H

00H

 

 

Bit5: Reserved

 

 

 

 

Bit4:

 

 

 

 

Bit3: ECP speed

 

 

 

 

Bit2:

 

 

 

 

Bit1: Compatibility speed

 

 

 

 

Bit0:

 

 

 

 

 

 

 

33H

Bi-D Adjustment 1

-36<=n<=+36 (by 1/2880inch)

00H

(*1)

 

for Multi Shot Bk

 

 

 

 

 

 

 

 

34H

Bi-D Adjustment 2

-36<=n<=+36 (by 1/2880inch)

00H

(*1)

 

for 6plVSD Bk

 

 

 

 

 

 

 

 

35H

Bi-D Adjustment 3

-36<=n<=+36 (by 1/2880inch)

00H

(*1)

 

for 4plVSD Bk

 

 

 

 

 

 

 

 

36H

Bi-D Adjustment for

-36<=n<=+36 (by 1/2880inch)

00H

(*1)

 

Multi Shot (Cl)

 

 

 

 

 

 

 

 

37H

Bi-D Adjustment for

-36<=n<=+36 (by 1/2880inch)

00H

(*1)

 

6plVSD (Cl)

 

 

 

 

 

 

 

 

38H

Bi-D Adjustment for

-36<=n<=+36 (by 1/2880inch)

00H

(*1)

 

4plVSD (Cl)

 

 

 

 

 

 

 

 

39H

1st dot Position

-36<=n<=+36 (by 1/2880inch)

00H

(*1)

 

Adjustment

 

 

 

 

 

 

 

 

3AH

CL2 Counter KK

 

00H

03H

 

 

 

 

 

Address

Explanation

Setting

QPIT

Factory

setting

setting

 

 

 

 

 

 

 

 

3BH

Total Timer CL

 

00H

00H

 

Counter

 

 

 

 

 

 

 

 

3CH

Printer For CSIC

 

00H

9EH:

 

 

 

 

World

 

 

 

 

19H:

 

 

 

 

Japan

 

 

 

 

 

3DH

CSIC1_InkName1;

 

00H

00H

3EH

CSIC2_InkName1;

 

 

 

 

 

 

 

 

3FH

Head Actuator Rank

+1<=n<=+32

00H

(*1)

 

ID for VhN

 

 

 

 

 

 

 

 

40H

Head Actuator Rank

+1<=n<=+37

00H

(*1)

 

ID for VhM

 

 

 

 

 

 

 

 

41H

Head Actuator Rank

+1<=n<=+34

00H

(*1)

 

ID for VhL

 

 

 

 

 

 

 

 

42H

Head Actuator Rank

+1<=n<=+34

00H

(*1)

 

ID for VhV

 

 

 

 

 

 

 

 

43H

Head Actuator Rank

+1<=n<=+40

00H

(*1)

 

ID for VhU

 

 

 

 

 

 

 

 

44H

Head Actuator Rank

+1<=n<=+34

00H

(*1)

 

ID for VhM2

 

 

 

 

 

 

 

 

45H

Head Actuator Rank

+1<=n<=+34

00H

(*1)

 

ID for VhB

 

 

 

 

 

 

 

 

46H

Head Actuator Rank

0<=n<=+6

00H

(*1)

 

ID for AR

 

 

 

 

 

 

 

 

47H

Head Actuator Rank

+30<=n<=+70

00H

(*1)

 

ID for IwB

 

 

 

 

 

 

 

 

48H

Head Actuator Rank

+30<=n<=+70

00H

(*1)

 

ID for IwC

 

 

 

 

 

 

 

 

49H

Head Actuator Rank

+30<=n<=+70

00H

(*1)

 

ID for IwM

 

 

 

 

 

 

 

 

Appendix

Connector Summary

141