EPSON Stylus PHOTO 810/820/830

Revision B

C H E

† When removing the Main board shield plate from the Main

P O I

board, pull the part indicated below vertically and remove it.

Pull

Figure 4-43. Main board shield plate removal

†When assembling the Main board to the M/B mounting plate,

„Make sure to set it to the M/B mounting plate correctly.

„Do not touch the LED on the Main board

†When assembling the Main board shield plate on the Main board,

„When the M/B mounting plate is removed from the Printer mechanism, the hook of the M/B mounting plate deforms. Therefore, you have to use new one.

„Make sure that the metal fittings for locking the Parallel interface is on its shield plate.

„Fasten four screws (C.B.S. SCREW 3x6 F/Zn,

C.B.S. SCREW 3x14 F/Zn) for securing the Main board shield plate and the Main board to the Main frame in the order indicated in the following figure.

3

1

Blue line marking side for P/S cable

4

2

Figure 4-44. Circuit board assembling

Tightening torque for each screw is as follows.

C.B.S. SCREW, 3x6, F/Zn (2 pcs) : 9 ± 1 kgf.cm

C.B.S. SCREW, 3x14, F/Zn (2 pcs) : 9 ± 1 kgf.cm

„Make sure to connect all cables to the connectors (CN2, CN4, CN7, CN8, CN9, CN12) on the Main board in the correct direction. (Refer to Figure 4-44)

†When assembling the SW button,

„Make sure that two hooks of the SW button is correctly fixed to the Main frame.

Disassembly and Assembly

Disassembly

112