„Fasten one screw (C.B.S. SCREW 3x6 F/Zn) for securing the Upper power supply shield plate to the Lower power supply shield plate. (Refer to Figure 4-25)

Tightening torque for screw is as follows.

• C.B.S. SCREW, 3x6, F/Zn (1 pcs) : 6 ± 1 kgf.cm

†When assembling the PSB/PSE unit to the Lower housing,

„Make sure to set the PSB/PSE unit under the protrusion of the Lower housing.

Hook

Figure 4-29. Power supply board shield plate setting position

„Make sure to connect the Power supply connector cable to the connector (CN2) on the Main board.

„Fasten two screws (C.B.P-TITE SCREW 3x8 F/Zn, C.B.S. SCREW 3x6 F/Zn) for securing the PSB/PSE unit to the Lower housing. (Refer to Figure 4-24)

Tightening torque for each screw is as follows.

C.B.P-TITE SCREW, 3x8, F/Zn (1 pcs) : 6 + 1 kgf.cm

C.B.S. SCREW, 3x6, F/Zn (1 pcs) : 6 + 1 kgf.cm

Disassembly and Assembly

Disassembly

106