6.10 Set unit “ESC (U nL nH m”

 

 

 

 

 

Format:

ESC

(

U

nL

nH

m

ASCII

Hex

1B

28

55

nL

nH

m

Decimal

27

40

85

nL

nH

m

Range of Values for Parameters: nL=01H, nH=00H

m=05H, 0AH, 14H, 1EH, 28H, 32H, 3CH (units 1/3600 inch) (=5, 10, 20, 30, 40, 50, 60)

Function:

1)Set the following standard units in units of 1/3600 inch: Relative horizontal position setting units

Absolute horizontal position setting units Relative vertical position setting units Absolute vertical position setting units Page management units

2)If nL or nH has a value other than the above, then the following (256 x nH + nL) bytes of data are received, and this command terminates.

3)If m has a value other than the above, this command is ignored.

Initial State:

Page management units: 1/360 inch Relative horizontal position setting units: Absolute horizontal position setting units: Relative vertical position setting units:

Absolute vertical position setting units:

Related Commands:

1/180 inch units 1/60 inch units 1/360 inch units 1/360 inch units

Commands related in the direction of applying an effect (Setting) None

Commands related in the direction of receiving an effect (Setting) None

Commands related in the direction of applying an effect (Operation)

The units for the relative horizontal position setting by the ESC \ command are set. The units for the absolute horizontal position setting by the ESC $ command are set. The units for the relative vertical position setting by the ESC (v command are set. The units for the absolute vertical position setting by the ESC (V command are set. The units for the "unit" unit page length specification by the ESC (C command are set. The units for the page format specification by the ESC (c command are set.

Commands related in the direction of receiving an effect (Operation) The initial state is returned to by the ESC @ command.

EPSON Imaging Technology Center