6.38 Set relative vertical position < MOVY >”

Format:

<011Fxxxx>B

Range of Values for Parameters:

If F=0: 0 ≤ parameter ≤ 15 (dot units)

If F=1: counter value=1, 2

Parameter=n1 or n1 + n2 x 256 (dot units) Function:

1)The parameter shows the relative unsigned vertical position from the current printing position in the Y direction.

2)The printing position in the Y direction is set to (the present position) + (the set displacement position).

3)The printing position in the X axis direction is set to the origin upon the X axis.

4)A setting of more than 44 inches is ignored.

Initial State: - Related Commands:

Commands related in the direction of applying an effect (Setting) None

Commands related in the direction of receiving an effect (Setting) None

Commands related in the direction of applying an effect (Operation) None

Commands related in the direction of receiving an effect (Operation) None

EPSON Imaging Technology Center

Page: 64

Revision: 1

10/6/00