Format: | ESC | ( | V | nL | nH | mL | mH |
ASCII | |||||||
Hex | 1B | 28 | 32 | nL | nH | mL | mH |
Decimal | 27 | 40 | 86 | nL | nH | mL | mH |
Range of Values for Parameters: |
|
|
|
|
|
| |
nL=02H, nH=00H |
|
|
|
|
|
|
(Vertical position set) = (mL + mH x 256) x (units set)
Function:
1)The printing position in the Y direction is set to a position spaced in the positive direction by (256 x mH + mL) x (the set absolute vertical position unit) inches from the origin upon the Y axis of the position management coordinate system.
2)If the printing position in the Y direction has been set by this command to a non- printable region, then the paper is ejected, the position management coordinate system is set to the next page, and the printing position in the Y direction is reset to the origin upon the Y axis of the new position management coordinate system.
3)Setting in the negative direction is ignored.
Initial State: -
Related Commands:
Commands related in the direction of applying an effect (Setting) None
Commands related in the direction of receiving an effect (Setting) None
Commands related in the direction of applying an effect (Operation) None
Commands related in the direction of receiving an effect (Operation) The absolute vertical position unit are set by the ESC( U commands.
The range of impossible printing are set by the ESC( c, ESC N, ESC O commands. The relative vertical position setting units, the
EPSON Imaging Technology Center | Page: 32 |
Revision: 1 | 10/6/00 |