6.28 Set relative horizontal print position “ESC \ nL nH”

Format:

ESC

\

nL

nH

ASCII

Hex

1B

5C

nL

nH

Decimal

27

92

nL

nH

Range of Values for Parameters:

(nL + 256 x nH) x (set units) inches Function:

1)If bit 6 of nH is 1, this is taken as meaning that a negative value has been set, and it is considered that the MSB of nH is 1. Negative values are expressed in two's complement.

2)The printing position in the X direction is set to a position spaced in the positive

direction from the present printing position in the X direction by (256 x nH + nL) x (the set relative horizontal position setting unit).

Set the defined unit with the ESC (U command.

The default defined unit for this command is 1/180inch.

3)If the position setting due to this command is within the non-printable region, it is ignored. However, it is possible to shift to a position on the right margin position.

Initial State: - Related Commands:

Commands related in the direction of applying an effect (Setting) None

Commands related in the direction of receiving an effect (Setting) None

Commands related in the direction of applying an effect (Operation) None

Commands related in the direction of receiving an effect (Operation)

The relative horizontal position setting units are set by the ESC (U command. The relative horizontal position setting units are reset to the initial state by the ESC @ and the ESC (G command.

EPSON Imaging Technology Center

Page: 53

Revision: 1

10/6/00