Format: | E | X | 03H | 00H | 00H | m1 | m2 |
ASCII | |||||||
Hex | 45 | 58 | 03 | 00 | 00 | m1 | m2 |
Decimal | 69 | 88 | 3 | 0 | 0 | m1 | m2 |
Parameters:
*Each of the parameters m1 and m2 is a one byte binary format parameter, and these select the mechanical sequence as follows:
m1 | m2 | Mechanical | Selection |
|
| sequence |
|
00H | 00H | Paper feed | Default |
00H | 01H | Plain paper | |
00H | 02H | sequence | Postcards |
00H | 03H |
| Film paper |
00H | 04H |
| Envelopes |
00H | 05H |
| Plain Paper( Load Quickly) |
00H | 06H |
| Back light film |
00H | 07H |
| Mat paper |
00H | 08H |
| Photo paper |
01H | 00H | Platen gap | Default ( t=0.1 ) |
01H | 01H |
| Gap1 ( t=0.2 ) |
01H | 02H |
| Gap2 ( t=0.3 ) |
02H | 00H | Paper loading | Default ( Normal ) |
|
| speed |
|
02H | 01H |
| Speed1 ( Fast ) |
02H | 02H |
| Speed2 ( Slow ) |
03H to | - | Reserved | - |
FFH |
|
|
|
*With the EPSON Stylus Photo 870, the paper feed sequence shown in Section 2.3, "Paper Feed Mode", according to the paper size and type, must be selected.
[Function]
*Changes the mechanical sequence for the default environment to the value specified by m1 and m2.
*If the parameter is out of range (03H - FFH), this command is ignored, and the previous setting is maintained.
*This command is only valid in remote mode.
EPSON Imaging Technology Center | Page: 72 |
Revision: 1 | 10/6/00 |