88

List of ESC/VP21 Commands

Command List

When a power ON command is sent to the projector, the power for the

projector turns on. When the projector is in a command ready state, it

returns the "3Ah" (:) code. Furthermore, when command processing is

complete, the projector also returns a ":" code.

The ":" code status can be used to determine whether the projector is ready

or busy. If command processing terminates with an error, an error message

is output and then the ":" code is sent.

Communication Protocol

Item Command
Power ON/OFF ON PWR ON
OFF PWR OFF
Signal selection
Computer SOURCE 11
Component Video (YCbCr) SOURCE 14
Component Video (YPbPr) SOURCE 15
Video SOURCE 41
S-Video SOURCE 42
A/V Mute ON/OFF ON MUTE ON
OFF MUTE OFF
A/V Mute Selection
Black MSEL 00
Blue MSEL 01
User's Logo MSEL 02
Standard baud rate : 9600 bps
Data length : 8 bits
Parity : None
Stop bit : 1 bit
Flow control : None
Connector shape : D-Sub 9-pin (male)
Projector input port : Control (RS-232C)