3. Installation

3.2.2 Mounting Holes

Refer to 2.3.3 Panel Cutout Dimensions for machining the mounting parts.

-Prepare the gasket and mounting metal hasps to install the Operator Panel.

-To ensure drip-proof performance, install the Operator Panel on a flat surface free of warping, scratches and unevenness. Attaching a stiffening plate is effective to prevent warping.

-The panel thickness range should be from 1.6 to 5.0 mm. Choose a panel thickness taking

the strength of the panel into consideration.

1.65.0mm

-For easier maintenance, operation, and improved ventilation, make sure to install the Operator Panel at least 100 mm away from surrounding structures and other equipment.

[Unit : mm]

100

100

100

 

100

 

100

100

100

-Use the Operator Panel within the operating ambient temperature range of 5 to 40 degC and operating ambient humidity range of 20 to 80%. The Operator Panel may malfunction if it is used outside of these ranges. (The operating ambient temperature range applies to both inside the Controller Box and outside the Controller Box.)

Inside Outside

Controller Controller

Box Box

-Prevent the Operator Panel from overheating due to heat generated by surrounding equipment.

10

OP1 Rev.1a