6. Maintenance and Inspection

6.5 About Gasket

NOTE

)

The gasket is used for dust-proof and dip-proof performance.

-Gasket that is used for long periods of time or once has been installed on the panel is scratched or dirty, and may not qualify IP65 dust-proofing and drop-proofing performance. Replace the gasket periodically* for stable dust-proof and dip-proof performance.

*Periodically: Yearly, or when obvious scratches or dirt is seen.

-The drip-proof performance (IP65 equivalent) is assured only when the gasket is mounted properly to the groove.

Replacement Procedure

(1)Put the Operator Panel on a horizontal place with the display side down.

(2)Remove the gasket.

Gasket

(3) Insert new gasket.

NOTE

)

-Do not insert the seams of the gasket at the corners of the Operator Panel.

-Attach the gasket so that its seams come to the bottom side the Operator Panel.

Seams

(4)Make sure to check the mounting condition of the gasket.

(The gasket evenly sticking out

 

3.0mm

approximately 3.0 mm from the groove)

 

 

 

 

 

 

 

 

 

 

OP1 Rev.1a

35

Page 43
Image 43
Epson RC170 manual About Gasket, Replacement Procedure, Gasket evenly sticking out