2. Specifications
2. Specifications
2.1Specification Tables
2.1.1Electrical Specifications
Item | Specifications |
Rated voltage | DC 24 V |
Voltage range | DC 21.6 to 26.4 V |
Power consumption | 7 W or less |
Dielectric strength | AC 500 V 20 mA per minute (across charger and FG terminals) |
Insulation resistance | 500 VDC 20 MΩ or more (across charger and FG terminals) |
2.1.2 Environmental Specifications
Item | Specifications |
Ambient temperature | 5 to 40 deg C (with minimal variation) |
(in panel and at sides of |
|
display screen) |
|
Storage ambient | −25 to 55 deg C |
temperature |
|
Operating ambient | 20 to 80% (no condensation) |
humidity |
|
Storage ambient | 20 to 80% (no condensation) |
humidity |
|
Dust | 0.1 mg/m3 or less (no conductive dust) |
Contamination level | 2 |
Corrosive gasses | Free of corrosive gasses |
Air pressure resistance | 800 to 1114 hPa (Max. 2000 m) |
(operation altitude) |
|
Noise resistance | 1 kV |
Electrostatic discharge | 4 kV |
immunity |
|
2.1.3 Appearance Specifications
Item | Specifications |
Protective structure* | JEM1030 IP65 or equivalent NEMA#250 TYPE4X/12 |
External dimensions | W215 mm ⋅ H155 mm ⋅ D46 mm (excluding connector hood) |
Weight | Approx. 800 g (Including Bypass Plug. Excluding the cable.) |
Cooling method |
*The protective structure is for the front part when the Operator Panel is installed. Though conformity has been confirmed under applicable testing conditions, use under all environments is not guaranteed. Before you start to use the Operator Panel, confirm use in the operating environment. Also, gasket that is used for long periods of time or once has been installed on the panel is scratched or dirty, and may cause lose sufficient protection performance. To ensure consistent protection performance, replace the gasket periodically.
4 | OP1 Rev.1a |