5. Programming for Operator Panel

B: Executing the display device selection command

Same as the Print command, display device can be switched by the DispDev command.

Integer

OfsQty

 

DispDev

23

Set the Operator Panel as the display device.

Print “Input the offset travel.”

Input OfsQty

5.2.1 Value Input

Integer numbers can be input from the Operator Panel.

When the value input command (Input #23, a) is executed in the application, the value input

area is displayed on the application screen of the Operator Panel.

If you touch this input area, the value input pallet is displayed. Use the value input palette to

input the required values, and apply the input data by the button on the right side of the value input pallet.

Integer a

a = 5

Input #23, a

You can display default data in the input area on the Operator Panel by substituting the values to be input with data before executing the Input command.