3.4 ALARM SETUP MENU

In the ALARM SETUP MENU, we define :

(1) ALARM:

ENABLE: Enable alarm detection.

DISABLE: Disable alarm detection.

(2)ALARM TYPE:

N. O. : Normal Open alarm.

N. C. : Normal Close alarm.

N.O. Trans.: When the alarm is triggered, buzzer starts to function no matter how long the alarm duration is set until you set it back to N.O.

N.C. Trans.: When the alarm is triggered, buzzer starts to function no matter how long the alarm duration is set until you set it back to N.C.

(3)ACTIVE CAMERA:

Active camera setting, from camera 01~08. You can set the camera which corresponds to the place where the alarm is located.

Note: The recording camera number in an event depends on the alarm number, and the active camera images will not be recorded. Example: You assign camera 3 as the active camera to alarm 1. When the alarm 1 is triggered, camera 3 will be displayed and camera 1 will be recorded.