EverFocus EMV400 user manual 15 Alarm - Event - HD Off

Models: EMV400

1 129
Download 129 pages 3.46 Kb
Page 54
Image 54
HD Off:

HD Off:

Figure 4-15 Alarm – Event - HD Off

Buzzer: Check box to enable buzzer if the hard drive is turned off (disconnected) or becomes disabled (cannot be detected by the system).

Email Notify: Check box to enable email notification when HD is off. Email operation requires that valid email settings have been entered in the Network Setting/Email setup screen.

Network Alarm: Check box to send out a network alarm to client PC. (requires PowerCon software and setting up Alarm Server in Network Setup menu)

Alarm Output: This will transmit a signal through the alarm output relay. It can be set to either “NONE” (not active), “1”(active) or “2” (active).

Output Type: Output action when alarm is triggered. Timeout: Alarm output lasts for the set time duration.

Permanent: Alarm will be continuously active until user presses “Enter” key.

Transparent: Alarm output remains active until event ends.

Trans+Timeout: Alarm output continues until event ends, then lasts for the set time duration.

Timeout Duration: The amount of time the buzzer sounds when the HD is off. Duration selectable from 1 to 150 seconds.

Click Figure 4-15 Alarm – Event - HD Off button to return to the previous level of menu.

46

Page 54
Image 54
EverFocus EMV400 user manual 15 Alarm - Event - HD Off