EverFocus EMV400 user manual Alarm-GPS Event Action, 22 Alarm - GPS Event Action

Models: EMV400

1 129
Download 129 pages 3.46 Kb
Page 62
Image 62
4.4.6 Alarm-GPS Event Action

4.4.6 Alarm-GPS Event Action

Press Figure 4-22 Alarm – GPS Event Action to enter GPS Event Action Menu.

Figure 4-22 Alarm – GPS Event Action

Alarm Output: This will transmit a signal through the alarm output relay. It can be set to either “NONE” (not active), “1” (active) or “2” (active).

Output Type: Output action when alarm is triggered. Timeout: Alarm output lasts for the set time duration.

Permanent: Alarm will be continuously active until user presses “Enter” key.

Transparent: Alarm output remains active until event ends.

Trans+Timeout: Alarm output continues until event ends, then lasts for the set time duration.

Timeout Duration: The amount of time the buzzer sounds when GPS event occurs. Duration selectable from 1 to 150 seconds.

Pre-alarm Record: Check box to start copying recorded video to the hard disk from 5 seconds before the video loss. (Pre-alarm recording rate will follow the “Normal” frame rate setting)

Email Notify: Check box to enable email notification when GPS event occurs. Email operation requires that valid email settings have been entered in the Network Setting/Email setup screen.

Network Alarm: Check box to send out a network alarm to client PC. (requires PowerCon software and setting up Alarm Server in Network Setup menu)

Click Manual background button to return to the previous level of menu.

54