Programmming Guide, cont’d
Establishing a connection
Establish a network connection to BME 0 as follows:
1. Open a TCP socket to port 23 using the IP address of the BME.
NIf the local system administrators have not changed the value, the factory- specified default, 192.168.254.254, is the correct value for this field.
The BME responds with a copyright message including the date, the name of the product, firmware version, part number, and the current date and time.
NIf the BME is not
NIf the BME is
2. If the BME is password protected, enter the appropriate administrator or user password.
If the password is accepted, the BME responds with Login User or Login Administrator.
If the password is not accepted, the Password prompt reappears.
Number of connections
The BME can have up to 200 simultaneous TCP connections, including all http sockets and Telnet connections. When the connection limit is reached, the switcher accepts no new connections until some have been closed. No error message
or indication is given that the connection limit has been reached. To maximize performance of an IP Link device, the number of connections should stay low and unnecessary open sockets should be closed.
Host-to-Switcher Instructions
The switcher accepts commands through the either of the