Extron electronic DMP 44 LC manual Power Supply Wiring

Models: DMP 44 LC

1 81
Download 81 pages 20.93 Kb
Page 12
Image 12
Figure 2. Power Supply Wiring

2-Pole Captive Screw

Connector

Tie Wrap

 

SECTION A–A

 

3/16”

 

(5 mm) Max.

Smooth

 

 

Ridges

A

A

Power Supply

Output Cord

Figure 2. Power Supply Wiring

Manual background WARNING: The two power cord wires must be kept separate while the power supply is plugged Manual backgroundin. Remove power before wiring.

CAUTIONS: • Always use a power supply supplied by or specified by Extron. Use of an unauthorized power supply voids all regulatory compliance certification and may cause damage to the supply and the end product.

Unless otherwise stated, the AC/DC adapters are not suitable for use in air handling spaces or in wall cavities. The power supply is to be located within the same vicinity as the Extron AV processing equipment in an ordinary location,

Pollution Degree 2, secured to the equipment rack within the dedicated closet, podium or desk.

The installation must always be in accordance with the applicable provisions of National Electrical Code ANSI/NFPA 70, article 75 and the Canadian Electrical

Code part 1, section 16. The power supply shall not be permanently fixed to building structure or similar structure.

CAUTION: When connecting the power supply, voltage polarity is extremely important. Applying power with incorrect voltage polarity could damage the power supply and the DMP 44 LC. Identify the power cord negative (ground) lead by the ridges on the side of the cord or a black heat shrink wrapping around it.

CAUTION: The length of the exposed (stripped) copper wires is important. The ideal length is 3/16 in (5 mm). Longer bare wires can short together. Shorter wires are not as secure in the direct insertion connectors and could be pulled out.

Do not tin the stripped power supply leads. Tinned wires are not as secure in the captive screw connectors and could be pulled out.

Manual background NOTE: To verify the polarity before connection, check the no load power supply output with a Manual background voltmeter.

Use the supplied tie-wrap to strap the power cord to the extended tail of the connector.

NOTE: To avoid losing adjustments when configuring the DMP 44 LC via

 

SIS commands issue a 2FF or if using the DSP Configurator, select

 

Tools > Save Changes to Device to store the latest changes to the

 

device. Wait several minutes after saving the adjustments before disconnecting

 

power.

 

DMP 44 LC • Installation

6

Page 12
Image 12
Extron electronic DMP 44 LC manual Power Supply Wiring