Extron electronic DMP 44 LC manual Digital Input Commands

Models: DMP 44 LC

1 81
Download 81 pages 20.93 Kb
Page 51
Image 51
Digital Input Commands

Digital Input Commands

Command

ASCII Command

Response

Additional Description

 

(Host to Tuner)

(Tuner to Host)

 

 

 

 

 

 

 

 

 

Configure digital input

EX!* X@* X#* X$GPIT}

GPITX!* X@* X#* X$]

See table below

 

EX!

GPIT

}

X@

**

 

View digital input

 

X# X$]

View digital input

 

Vrbmode2/3:

GPIT X!* X@*X#*X$]

 

View I/O state

X!*]

 

 

X%]

View I/O state

 

Vrbmode2/3:

Sio X!* X%

 

Digital Input Command Table

X!

=

Digital inputs 1–3

Inputs 1–3

 

X@

=

Type of signal change to monitor for

0 = off (default)

3 = level lo

 

 

 

1

= edge, hi to lo

4 = level hi

 

 

 

2

= edge, lo to hi

 

 

 

 

 

 

X#

=

Function

0 = off (default)

3 = decrement group

 

 

 

1

= mute/unmute group

4 = preset recall

 

 

 

2

= increment group

 

X$

=

Preset or group number

preset range = 1–16

 

 

 

 

group range = 1–16

 

 

 

 

0

= off (default)

 

X%

=

State

0 = hi (voltage)

 

 

 

 

1

= lo (voltage)

 

DMP 44 LC • SIS Programming and Control