Extron electronic GSS 100 Graphic Still Store SIS Control, 4-11, SIS Control, cont’d, Command

Models: GSS 100

1 45
Download 45 pages 22.45 Kb
Page 25
Image 25
4-10 GSS 100 Graphic Still Store • SIS™ Control

4-10 GSS 100 Graphic Still Store • SISControl

Command/response table for SIS commands (continued)

Command

ASCII Command

Response

Additional description

 

(host to switcher)

(switcher to host)

 

 

 

 

 

Output rate

 

 

 

Set the output rate

X%*X^=

RteX%X^]

Set the output resolution for the stored image to X%

 

 

 

at X^ Hz.

NThe output rate (=) command affects the display of the stored images only; pass-through images are output exactly as they are input.

Example:

3*1=

Rte3•1]

Set the output resolution for the stored image to

 

 

 

1024 x 768 at 60 Hz.

View output rate

=

X%X^]

The stored image’s output resolution is X% at X^ Hz.

 

 

 

 

Output sync

 

 

 

Set the output sync format

6*X&#

TpoX&]

Set the stored image’s output sync format to X&.

NThe output sync format (6#) command affects the display of the stored images only; pass-through images are output exactly as input.

Example:

6*0#

Tpo0]

Set the stored image’s output sync format to RGBHV.

View output sync format

6#

X&]

The stored image’s output sync format is X&.

Set the ouput sync polarity

7*X*#

PolX*]

Set the stored image’s output sync format to X*.

NThe output sync polarity (7#) command affects the display of the stored images only; pass-through images are output exactly as input.

Example:

7*0#

Pol0]

Set the stored image’s output sync polarity to H - and V -.

View output sync polarity

7#

X*]

The stored image’s output sync polarity is X*.

RGB delay (pass-through)

 

 

Set RGB delay

8*X##

Dly]

Set the RGB delay (video mute) before displaying the

 

 

 

RGB pass-through input to X#.

Read RGB delay

8#

X#]

 

Video mute

 

 

 

Mute video

1B

Vmt1]

Video mute on.

Unmute video

0B

Vmt0]

Video mute off.

Read video mute status

B

X@]

Video mute status.

SISControl, cont’d

Command/response table for SIS commands (continued)

Command

ASCII Command

Response

Additional description

 

(host to switcher)

(switcher to host)

 

 

 

 

Front panel lockout (Executive mode)

 

 

Lock front panel

1x

Exe1]

Lock front panel.

Unlock front panel

0x

Exe0]

Unlock front panel.

Read front panel lock status

x

X@]

Read front panel lock: 1 = locked, 0 = unlocked.

GSS 100 Graphic Still Store • SISControl

Event (script) control

Read event buffer memory

Read event status

Write event to memory buffer

Read string from event buffer memory

Write string to event buffer memory

Start events Stop events

Read number of events running

EX1@,X1#,X1$,X1%E}

X1(]

EX1@E} X1*]

EX1@,X1#,X1$,X1^,X1%E}

EwrX1@,X1^]

EX1@,X1#,X1$,X1&FE}

{string}]

EX1^,X1@,X1#,X1$FE}

EwrX1@,X1^]

E1AE} Ego]

E0AE} Est]

EAE} Enm##]

Read the contents of a specific section of a memory buffer for event number X1@.

Show the status of event X1@. The following X1* information fields are displayed: event_type, event_state, event_paused, error_status, RcvBuff_startptr, cvBuff_endptr, UsrBuff_startptr, and UsrBuff_endpt.

Write event X1@ to buffer X1#, offset by X1$. Include data X1^, size X1%.

Read string from event X1@, buffer X1#, offset by X1$, X1& bytes.

Write data string X1^ from event X1@, buffer X1#, offset by X1$.

Initiate all programmed events. Stop all programmed events.

4-11

Page 25
Image 25