Extron electronic GSS 100 user manual Installation, cont’d, Reset button, firmware

Models: GSS 100

1 45
Download 45 pages 22.45 Kb
Page 12
Image 12
Installation, cont’d

Installation, cont’d

Patch (straight) cable

 

 

 

 

 

 

Side 1

 

 

Side 2

 

 

 

 

 

Pin

Wire color

 

Pin

Wire color

 

 

 

 

 

1

White-orange

 

1

White-orange

Side

Clip Down

 

 

 

 

 

 

 

2

Orange

 

2

Orange

 

Pins

1 2 3 4 5 6 7 8

 

RJ-45

 

 

 

 

 

 

 

 

 

 

3

White-green

 

3

White-green

 

 

 

 

 

 

 

 

 

connector

 

 

 

 

 

 

 

 

 

 

4

Blue

 

4

Blue

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

White-blue

 

5

White-blue

 

 

 

 

 

6

Green

 

6

Green

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

White-brown

 

7

White-brown

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

Brown

 

8

Brown

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reset button

F

Reset button — The Reset button initiates three levels of reset to

 

the GSS. Press and hold the button while the GSS is running or

 

while you power up the GSS for different reset levels.

 

Events (mode 3) reset — Hold the Reset button for

 

approximately 3 seconds (the Reset LED blinks once),

 

then release it and push it again to toggle events

 

monitoring on and off.

 

IP settings (mode 4) reset — Hold the Reset button for

 

approximately 6 seconds (the Reset LED blinks twice),

 

then release it and push it again to reset the GSS’s IP

 

functions.

 

N The IP settings reset does not replace any user-installed

1 2 3 4 5 6 7 8

1&2Reset button• IP settings (mode 4) reset — Hold the Reset button forN The IP settings reset does not replace any user-installedfirmware. 3&6 4&5 7&8

Crossover cable

 

 

Side 1

 

 

Side 2

 

Pin

Wire color

 

Pin

Wire color

 

1

White-orange

 

1

White-green

Twisted

 

 

 

 

 

2

Orange

 

2

Green

Pairs

 

 

 

 

 

3

White-green

 

3

White-orange

 

 

 

 

 

 

 

 

 

4

Blue

 

4

Blue

 

 

 

 

 

 

 

5

White-blue

 

5

White-blue

 

 

 

 

 

 

 

6

Green

 

6

Orange

 

7

White-brown

 

7

White-brown

 

 

 

 

 

 

 

8

Brown

 

8

Brown

 

 

 

 

 

 

firmware.
Absolute (mode 5) reset — Hold the Reset button for
approximately 9 seconds (the Reset LED blinks three times),
then release it and push it again to restore the GSS to the
default factory conditions.
N Image files, IP settings, and user settings are all cleared
and reset to the factory default.
Figure 2-4RJ-45 connector and pinout tables

E

RS-232 port — Connect a computer or control system to

 

this 9-pin D connector to allow remote control using the SIS

 

commands (figure 2-5). See chapter 4, SIS™ Control, for details.

 

PIN

RS-232

Function

 

1

None

RS-232

2

TX

Transmit data

3

RX

Receive data

 

 

4

None

 

5

Gnd

Ground

 

6

None

 

7

None

 

8

None

 

9

None

Figure 2-5RS-232 connector pinout