Operation

Front Panel Controls and Indicators

Figure 3-1 shows the controls and indicators on the front panel of the GSS 100. See Front Panel Operations for details on using these controls and indicators.

 

 

 

GSS 100

IMAGE

TAKE

MENU

NEXT

 

 

 

ADJUST/

 

 

 

SELECT

 

1

2

3

4

5

6

 

Figure 3-1 — GSS 100 front panel

 

 

 

A

Image button — Press this button to activate the menu on the

 

LCD display (C) that allows you to select between the pass-

 

through input and one of the stored images.

 

 

 

B

Take button — Press this button to select either the pass-

 

 

through input or one of the stored images.

 

 

 

C

LCD display — The 8-column by 2-line LCD screen displays

 

output and configuration menus and status information.

 

D

Menu button — Press the Menu button to enter and move

 

through the main menu system in the GSS.

 

 

 

E

Next button — Press the Next button to step through the

 

 

submenus in the GSS menu system.

 

 

 

F

Adjust/Select knob — Rotate the Adjust/Select knob to change

 

settings when it is used in conjunction with the Image and Take

buttons or the Menu and Next buttons.

Front Panel Operations

Plug in all system components and turn on the input device (such as a desktop or laptop computers) and the output monitor. Use the LAN port to upload one or more still images to the GSS. Select either the pass-through input or one of the stored still images to output (see Selecting an image to display). The image should appear on the monitor connected to the output.

Power-on indications

Power is applied when the power cord is connected to an AC source. When AC power is applied, the GSS performs a self-test that shows the model name and the firmware version in the LCD display. After approximately 3 seconds, the LCD reverts to its default display cycle, alternating among four displays that show the model name, the currently displayed image (the pass- through input or one of the previously loaded images by its file name), the output resolution (of a stored image only; the pass- through input is output exactly as it is input), and the unit’s IP address (figure 3-2).

The current settings are saved in nonvolatile memory. When power is applied, the latest configuration is retrieved.

NOn figure 3-2 and all other flowcharts in this chapter, dashed lines indicate screen changes that are the result of a timeout function.

Power

on

Extron

 

 

Default Cycle

 

GSS 100

 

 

 

 

Viewing

 

3 sec.

 

 

 

 

 

 

 

 

 

PassThru

 

Version

3 sec.

Extron

3 sec.

 

or

3 sec.

n.nn

 

GSS 100

 

 

Viewing

 

 

 

 

 

 

Image

 

 

 

 

1024 x

3 sec.

I192.168 3 sec.

 

 

 

768

@72

P255.255

or

RGB

PASSTHRU

Figure 3-2 — LCD power-on displays and default display cycle

3-2

GSS 100 Graphic Still Store • Operation

GSS 100 Graphic Still Store • Operation

3-3

Page 14
Image 14
Extron electronic GSS 100 user manual Front Panel Controls and Indicators, Front Panel Operations, Power-on indications

GSS 100 specifications

Extron Electronics GSS 100 is a powerful yet compact audio signal distribution system designed to enhance the audio experience in various applications, from classrooms to corporate environments. Known for its reliability and performance, the GSS 100 serves as an essential component for signal management in modern AV systems.

One of the main features of the GSS 100 is its capability to distribute audio signals to multiple outputs while maintaining high fidelity. With the ability to handle both balanced and unbalanced signals, the GSS 100 can adapt to various audio sources and systems. This flexibility makes it suitable for a wide range of applications, including live events, presentation venues, and educational institutions.

The GSS 100 utilizes Extron’s advanced audio processing technology, which includes built-in audio mixing, equalization, and signal routing capabilities. Users can easily manage audio levels and blend multiple audio sources to create a seamless listening experience. This is particularly beneficial in environments where sound quality is paramount, allowing for adjustments that optimize the auditory experience for the audience.

Another characteristic that sets the GSS 100 apart is its intuitive user interface. The device features a straightforward control system, making it easy for users to manage and configure settings without extensive technical knowledge. Additionally, the unit is built for quick installation, with both rear and front panel connections for flexible installation options. This design consideration helps streamline setup time and minimizes disruption.

The GSS 100 also integrates seamlessly with other Extron and third-party products, enhancing its versatility in complex AV systems. With various input and output configurations, users can connect the GSS 100 to microphones, mixers, and amplifiers effortlessly. Its ability to connect to networked AV systems further extends its capabilities, enabling remote monitoring and control through software interfaces.

In conclusion, the Extron Electronics GSS 100 stands out as a premier audio signal distribution system that combines advanced technology with user-friendly features. Whether for educational purposes, corporate events, or live productions, the GSS 100 delivers reliable performance and exceptional audio quality, ensuring an optimal listening experience for any audience. As a result, it remains a popular choice among AV professionals seeking to elevate their systems with efficient and effective audio management solutions.