Image 31

HTML Control and IPL File Manager

The GSS can be configured through its Ethernet port, connected via a LAN or WAN and using a web browser such as Microsoft’s Internet Explorer. The browser’s display of the GSS’s configuration has the appearance of web pages. This chapter describes the factory-installed HTML pages, which are always available and cannot be erased or overwritten.

NIf your Ethernet connection to the GSS is unstable, try turning off the proxy server in your Web browser. In Microsoft’s Internet Explore, click

Tools > Internet Options > Connections > LAN Settings, uncheck the “Use a proxy server...” box, and then click the Ok button.

Configuring the Hardware

To function properly, the controlling PC and the GSS must be configured correctly: the PC must be network capable, with the proper protocols installed, and the hardware configured correctly. The GSS must also be set to recognize and accept commands.

PC configuration

This manual assumes that you have a Windows PC equipped with an operating network adapter. To allow your PC to work with Extron’s Ethernet-controlled products, the TCP/IP protocol must be installed and properly configured.

For use on an existing Ethernet LAN intranet, your network administrator can provide you wih a unique IP address or confirm whether you need to set up the GSS for Dynamic Host Configuration protocol (DHCP) to have an address assigned automatically when you sign on.

Initial startup

When you power on the GSS for the first time, there are two ways to set up the IP address:

Use the ARP command method.

Use the direct PC method.

The default Web pages that are pre-loaded in the GSS provide a way to reconfigure the GSS once it has an active network connection with IP access. These Web pages are compatible with Netscape Navigator (version 6.0 or higher) or Internet Explorer (version 5.5 or higher).

Once the GSS has been configured, an Ethernet (intranet or Internet) connection can subsequently be used to contact or control it.

GSS configuration

Configuring the GSS using the ARP command

You can use the Address Resolution Protocol (“ARP”) command to set up an IP address for your GSS. The ARP command associates the GSS’s MAC address with the assigned IP address in your computer. You must then use the “ping” command to access the GSS, at which point the device server’s IP address is reconfigured.

NTo use this setup method, either your PC and the GSS must be connected to the same LAN or you may use a crossover Ethernet cable to connect the two devices. See Cabling and RJ-45 connector wiring in chapter 2, Installation.

Use the ARP command to configure the IP address as follows:

1.

Obtain a valid IP address for the GSS from your network

 

administrator.

2.

Obtain the GSS’s MAC address (UID #) from the label on

 

the GSS’s rear panel.

3.

If the GSS has never been configured, and is still set to its

 

factory defaults, procede to step 4.

If the GSS has previously been configured, perform an IP settings (mode 4) reset. See Reset button, in chapter 2, Installation.

CYour GSS must be configured with the default IP address (192.168.254.254) before executing the ARP command.

4.

Click Start > Run... to activate the Run window. Type Cmd

 

in the Run window and click OK to access the MS-DOS

 

command prompt.

 

 

 

 

 

5.

Enter the ARP -s command with the desired new IP

 

address (obtained from the system administrator) and

 

the GSS’s MAC address (from the label on the GSS’s rear

 

panel), as follows:

 

 

 

 

 

 

 

C:\> arp -s 10.13.170.15 00-05-A6-00-0A-90 {Enter}

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Command

Desired

 

MAC address

Enter

 

Prompt

IP address

 

 

 

key

5-2 GSS 100 Graphic Still Store • HTML Control and IPL File Manager

GSS 100 Graphic Still Store • HTML Control and IPL File Manager 5-3

Page 31
Image 31
Extron electronic GSS 100 Html Control and IPL File Manager, Configuring the Hardware, PC configuration, GSS configuration

GSS 100 specifications

Extron Electronics GSS 100 is a powerful yet compact audio signal distribution system designed to enhance the audio experience in various applications, from classrooms to corporate environments. Known for its reliability and performance, the GSS 100 serves as an essential component for signal management in modern AV systems.

One of the main features of the GSS 100 is its capability to distribute audio signals to multiple outputs while maintaining high fidelity. With the ability to handle both balanced and unbalanced signals, the GSS 100 can adapt to various audio sources and systems. This flexibility makes it suitable for a wide range of applications, including live events, presentation venues, and educational institutions.

The GSS 100 utilizes Extron’s advanced audio processing technology, which includes built-in audio mixing, equalization, and signal routing capabilities. Users can easily manage audio levels and blend multiple audio sources to create a seamless listening experience. This is particularly beneficial in environments where sound quality is paramount, allowing for adjustments that optimize the auditory experience for the audience.

Another characteristic that sets the GSS 100 apart is its intuitive user interface. The device features a straightforward control system, making it easy for users to manage and configure settings without extensive technical knowledge. Additionally, the unit is built for quick installation, with both rear and front panel connections for flexible installation options. This design consideration helps streamline setup time and minimizes disruption.

The GSS 100 also integrates seamlessly with other Extron and third-party products, enhancing its versatility in complex AV systems. With various input and output configurations, users can connect the GSS 100 to microphones, mixers, and amplifiers effortlessly. Its ability to connect to networked AV systems further extends its capabilities, enabling remote monitoring and control through software interfaces.

In conclusion, the Extron Electronics GSS 100 stands out as a premier audio signal distribution system that combines advanced technology with user-friendly features. Whether for educational purposes, corporate events, or live productions, the GSS 100 delivers reliable performance and exceptional audio quality, ensuring an optimal listening experience for any audience. As a result, it remains a popular choice among AV professionals seeking to elevate their systems with efficient and effective audio management solutions.