Image 19
Mode 1

Mode 1

Activation

Hold in the Reset button while applying power to the unit.

 

 

Result

Returns the unit to the default base firmware that was shipped

 

with the PC1 from the factory. Event scripting does not start when

 

the unit is powered on in this mode.

 

 

Purpose and notes

Use mode 1 to remove a version of firmware if incompatibility

 

issues arise. All user files and settings are maintained. User web

 

pages may not work correctly if you are using an earlier firmware

 

version.

Activation NOTE: After a mode 1 reset, the factory-installed firmware version remains in effect

only until the unit is powered off. After a power cycle, the PC1 returns to the firmware that was installed prior to the mode 1 reset.

Mode 2

Activation

To enter mode 2, you use both the PC1 front panel and your

 

computer, as follows:

 

1. On the computer, open a command interface, such as Extron

 

DataViewer or HyperTerminal.

 

2. Immediately press the Reset button momentarily (for less than

 

1 second).

 

NOTE: Nothing happens if the momentary press does

 

not occur within 1 second.

 

3. Within 2 seconds of the momentary press, press the <+>

 

key on the computer keyboard three times.

Result

The RS-232 port is converted to a host port, which allows the use

 

of SIS commands and host responses.

 

No LEDs blink to indicate the mode switch. If the switch to mode 2

 

is successful and serial port communication is enabled, the interface

 

screen displays one of the following copyright messages:

 

(c) Copyright 2011, Extron Electronics, IPL T PC1,

 

Vn.nn, 60-544-nn

 

(c) Copyright 2011, Extron Electronics, IPL T PC1i,

 

Vn.nn, 60-544-nn

Purpose and notes By default, the RS-232 port is a device control port. In mode 2, the

 

serial port is able to receive SIS commands.

 

NOTE: If you do not enter the three plus (+) signs within 2

 

seconds of the momentary press of the Reset button,

 

the RS-232 port reverts to a device control port.

IPL T PC1 • Front Panel Features and Operation 13