Extron electronic IPL T PC1i Command and Response Table for SIS Commands, Sum of responses from

Models: IPL T PC1 IPL T PC1i

1 78
Download 78 pages 34.87 Kb
Page 60
Image 60
Command and Response Table for SIS Commands

Command and Response Table for SIS Commands

Command

ASCII (Telnet)

URL Encoded (web)

Response

(Host to Switcher)

(Host to Switcher)

(Switcher to Host)

 

Power Receptacle Control / Current Sense

Turn receptacle power on

E 1*1PC}

Turn receptacle power off

E 1*0PC}

View receptacle power status

E 1PC}

Set Executive mode on

1X

Set Executive mode off

0X

View Executive mode

X

W 1 %2A 1PC

W1 %2A 0PCW 1PC

1X

0X X

Cpn 01Ppc1]

Cpn 01Ppc0]

X% ]

Exe1]

Exe0]

X% ]

Power Receptacle Naming

 

 

 

Set receptacle name24

E 1,X71# NO}

W 1 %2C X71# NO

Nmo1, X71# ]

Set receptacle name to factory

E 1,NO}

W 1 %2C %20 NO

Nmo1, X71# ]

default24

 

 

 

View receptacle name

E 1NO }

W 1NO

X71# ]

Power Receptacle Scheduling

 

 

 

Set scheduling24

E 1*X71!*X%*X71@ SS}

W 1 %2A X71! %2A X% %2A X71@ SS

 

 

 

Set1*X71!*X%*X71@ ]

View scheduling

E 1*X71!*X% SS}

W 1 %2A X71! %2A X% SS

X71@ ]

Front Panel Lockout Scheduling (Executive Mode)

 

 

Set scheduling24

E 2*X71!*X%*X71@ SS}

W 2 %2A X71! %2A X% %2A X71@ SS

 

 

 

Set2*X71!*X%*X71@ ]

View scheduling

E 2*X71!*X% SS}

W 2 %2A X71! %2A X% SS

X71@ ]

Ethernet Data Port Commands

 

 

 

Set current connected port

E 0*X6( TC}

W 0 %2A X6( TC

Pti0*X6( ]

timeout

 

 

 

View current connected port

E 0TC}

W 0TC

X6( ]

timeout

 

 

 

Set global IP port timeout

E 1*X6( TC}

W 1 %2A X6( TC

Pti1*X6(

View global IP port timeout

E 1TC}

W 1TC

X6( ]

Information Requests

 

 

 

Sum of responses from NOTE: An asterisk (*) after a version number indicates the version that is currently running. Question marks (?.??)

indicate that only the factory firmware version is loaded. A caret (^) indicates the firmware version that should be

running; however, a mode 1 reset was executed and the factory default firmware version is currently loaded. An exclamation point (!) indicates corrupted firmware.

Query firmware version

Q

Q

X1! ]

 

 

 

With tagged response –

 

 

 

verbose modes 2 and 3:

 

 

 

Ver01*X1! ]

Query verbose version information

0Q

0Q

Sum of responses from

 

 

 

2Q, 3Q, and 4Q ]

 

 

 

With tagged response –

 

 

 

verbose modes 2 and 3:

 

 

 

Ver00*X1! sum of

 

 

 

responses from 2Q,

 

 

 

3Q, and 4Q ]

Query firmware information

1Q

1Q

X1! ]

With tagged response – verbose modes 2 and 3:

Ver01*X1! ]

IPL T PC1 • SIS Programming and Control 54

Page 60
Image 60
Extron electronic IPL T PC1i manual Command and Response Table for SIS Commands, Sum of responses from, responses from 2Q