Extron electronic IPL T PC1i manual Symbol Definitions, Example 11/18/03-105400

Models: IPL T PC1 IPL T PC1i

1 78
Download 78 pages 34.87 Kb
Page 56
Image 56
Symbol Definitions

Symbol Definitions

] = CR/LF (carriage return + line feed) (hex 0D 0A)

}= Soft carriage return (no line feed, hex 0D)

(For web browser commands, use the [pipe] character instead of the soft return.)

= Pipe (vertical bar) character

= Space

24= The 24 superscript indicates commands that give an E24 (privilege violation) message if you are not logged in at the administrator level.

E= Escape key (hex 1B) (For web browsers, use W instead of E. ) X! = Power receptacle (1-4)

X#

= Greenwich Mean Time (GMT) offset value

 

 

(‑12.00 to +14.00) represents the time difference in hours and minutes (±hh:mm) relative to Greenwich, England. The

 

 

plus sign and leading zero are optional. For example, 5:30 = +05:30.)

X%

= On or Off status

 

 

0

= off or disable

 

 

1

= on or enable

X^

=

Dirty memory status

 

 

1

= RAM needs to be saved to flash memory.

 

 

0

= RAM has been saved to flash (OK to power off or reset).

X(

=

Current threshold sense

 

 

0

= clear or none

 

 

1

= standby

 

 

2

= full

 

 

(Full threshold must be set before standby.)

X1)

=

Group number

 

 

0

= none

 

 

1

= yellow

 

 

2

= green

 

 

3

= red

 

 

(The exponent designates the port number. The color relates to setting groups via the front panel.)

X1! = Version (typically listed to two decimal places, that is, n.nn)

X1@

= Unit name. The name of the PC1 is a text string of up to 24 characters drawn from the alphabet (A-Z), digits (0-9),

 

 

and minus sign or hyphen (-). No blank or space characters are permitted as part of a name. No distinction is made

 

 

between upper and lower case.

 

 

NOTE: The first character must be a letter. The last character must not be a minus sign or hyphen.

X1#

= Local date and time format

 

 

Set format (MM/DD/YY-HH:MM:SS).

 

 

Example: 11/18/03-10:54:00.

 

 

Read format (day of week, day month year HH:MM:SS).

 

 

Example: Tue, 18 Nov 2011 18:19:33.

X1$

= IP address (nnn.nnn.nnn.nnn). Leading zeros in each of four fields are optional in setting values, and they are

 

 

suppressed in returned values.

X1%

= E-mail domain name (for example: extron.com)

X1^

= Power-up delay between ports in 1/3-second increments. 1-255permitted.

 

 

(Default is 3, which equals 1 second.)

IPL T PC1 • SIS Programming and Control 50

Page 56
Image 56
Extron electronic IPL T PC1i manual Symbol Definitions, Example 11/18/03-105400, Example Tue, 18 Nov 2011