Figure 11. Ping Command on a Command Prompt Screen

The response should be the new IP address of the PC1, as shown below.

Figure 11. Ping Command on a Command Prompt Screen

7.After verifying that the IP address change was successful, issue the arp -dcommand at the DOS prompt to remove the address from the computer ARP table.

For example:

arp -d 10.13.197.57

A space must separate arp from the hyphen (-).

Setting Up and Configuring the PC1 Using a Web Browser

To set up the PC1 for Ethernet communication using a web browser, you must temporarily configure the PC to communicate with the interface. Then you can change the default settings of the PC1 (IP address, subnet mask, and [optionally] administrator name and password) in order to use the unit on an intranet (LAN) or on the Internet (WAN). After you have set up the PC1 for network communication, you can reset the computer to its original network configuration.

IPL T PC1 LAN port defaults

PC1 IP address:

192.168.254.254

Gateway IP address:

0.0.0.0

Subnet mask:

255.255.0.0

DHCP:

Off

Link speed and duplex level:

Auto detected

If you use an existing Ethernet LAN intranet, your network administrator can provide you with a unique IP address for the PC1 or confirm whether you need to set up the PC1 for DHCP (Dynamic Host Configuration protocol) to have an address assigned automatically.