Example: 1439 = 11:59

X5(

=

IR Playback mode

 

 

0

= play once

 

 

1

= play continuously

 

 

Response is returned with leading zeros.

 

 

To stop mode 1 playback, send the IR command again with mode 0 selected.

X6$

=

Time in seconds to keep sending the broadcast message (0-255, default = 10)

X6(

=

(Ethernet only) Number of seconds before timeout on IP connections (min. = 1, max. = 6500, and

 

 

default = 30 = 300 seconds).

 

 

If no data is received during the timeout period, the Ethernet connection is closed. Each step is 10 seconds. The

 

 

response is returned with leading zeros.

X7)

=

The number (as an optional parameter) that is inserted into the e-mail message if the .eml file has an embedded

 

 

command (with no parameters).

X7!

=

Hardware (MAC) address: the four most significant hex nibbles converted into a single 16-bit decimal number.

X7@

=

Hardware (MAC) address: the eight least significant hex nibbles converted into a single 32-bit decimal number.

 

 

NOTE: This can be up to 10 digits.

X7#

=

E-mail account user name. Maximum length is 31 characters. This parameter is optional; commas cannot be used as

 

 

placeholders for it. If it is omitted from an issued command, any existing user account name is cleared.

X7$

=

E-mail account password. Maximum length is 31 characters. This parameter is optional; commas cannot be used as

 

 

placeholders for it. If it is omitted from an issued command, any existing user account password is cleared.

X71! = Days of the week

 

 

1

= Sunday

 

 

2

= Monday

 

 

3

= Tuesday

 

 

4

= Wednesday

 

 

5

= Thursday

 

 

6

= Friday

 

 

7

= Saturday

X71@

=

Time in minutes (0-1440)

 

 

0

= 12 am (midnight)

 

 

1440 = clear schedule

Example: 1439 = 11:59

Use the following formula (in 24-hour time format): (hour x 60) + minutes = time in minutes

X71# = Power receptacle name (12 characters maximum)