Reset Device

To set, change, or clear a user password you must be logged on as an admin.

1.Click Clear to clear a previous password, then type a password in the User Password: field. If this is the first time a password is set, type the password in the User Password: field.

2.Duplicate the password in the Confirm Password: field.

3.Click Save.

Reset Device

Provides several options to reset the SMD 101 if hardware or software conditions require.

NOTE: Proceed with caution. Some reset modes intentionally delete all user files, media content, and settings from internal memory.

Figure 39. Device Reset, Reset Options

Reset Device settings to default — Resets all hardware and software to default condition, but retains user files and IP settings for communication.

Reset Device settings and delete internal user files (Retains all IP settings) — Resets all hardware and software to default condition, deletes user files stored in internal memory, and retains IP settings for communication.

Reset Device settings, delete internal user files, and reset all IP settings — Resets all hardware and software to default condition including IP settings.

NOTE: If the control PC is connected via the Ethernet port, communications is broken. Use the default IP address (192.168.254.254), the front panel config port, or the rear panel RS-232 port to reconnect.

To select a reset, click the button to the left of the desired option. The radio button lights. Click Apply to begin the reset. See the SMD 101 Reset Summary on page 83 for a comparison of the reset modes.