The SMD 101 can be reset to default states using the rear panel reset button, the

Reset Device page of the user interface, and SIS commands. Each reset affects different configurations and local files, resetting some to factory condition and retaining others.

The reset mode summary table below details the activation, results, and purpose of each rear panel activated reset mode.

SMD 101 Reset Mode Summary

 

 

 

Mode

Activation

Result

Purpose and Notes

 

 

 

 

 

 

 

 

Firmware

 

1

Hold in the recessed rear panel

The SMD 101 reverts to the factory

If incompatibility issues arise with

 

 

reset button while applying

default firmware for a single power cycle.

user-loaded firmware, use mode 1

 

 

power to the unit.

 

 

to revert to the factory default

 

 

 

 

 

firmware for a single power cycle.

Factory

 

 

 

 

 

All user files and settings are

 

 

 

 

 

maintained.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Hold in the Reset button for

Mode 4:

Mode 4 is used to set

 

 

 

 

about 6 seconds until the Power

Sets port mapping back to factory

IP address information using ARP

 

 

 

 

LED blinks twice (once at 3

 

default.

and the MAC address.

 

 

 

 

seconds, again at 6 seconds).

 

 

 

Settings

 

 

Sets the IP address back to factory

"Resetting IP Settings" appears

 

 

Then, release and press Reset

 

 

on a connected display.

 

 

 

default (192.168.254.254).

 

 

again within

 

 

 

 

 

 

 

 

Sets the subnet mask address back

 

 

 

 

1 second*.

 

 

IP

 

 

 

 

to the factory default (255.255.0.0).

 

 

All

 

 

 

Sets the gateway IP address to the

 

 

Reset

 

 

 

 

 

 

 

 

 

factory default (0.0.0.0).

 

 

 

 

 

Turns DHCP off.

 

 

 

 

 

 

 

The Reset LED on the rear panel

 

 

 

 

 

 

 

 

of the unit flashes four times in

 

 

 

 

 

 

 

 

succession.

 

 

 

 

 

 

 

 

 

 

 

 

 

5

Hold in the Reset button for

Mode 5:

Mode 5 is useful when wanting to

Defaults

 

 

about 9 seconds until the Power

Performs a complete reset to factory

start over with configuration and

 

 

LED blinks three times (once at

uploading, and also to replace

 

 

defaults (except the firmware).

 

 

3 seconds, again at 6 seconds,

events.

 

 

Does everything mode 4 does.

 

 

again at 9 seconds). Then,

"Resetting SMD 101" appears on

Factory

 

 

release and press Reset again

Clears port configurations.

 

 

a connected display.

 

 

within

Resets all IP options.

 

 

 

 

 

 

1 second*.

 

 

 

 

Clears all user settings.

 

 

 

 

 

 

 

to

 

 

 

 

 

 

 

 

Clears all files from the unit.

 

 

Reset

 

 

 

 

 

 

 

 

The Reset LED on the rear panel

 

 

 

 

 

 

of the unit flashes four times in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

succession.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: * = For modes 4 and 5, nothing happens if the momentary press does not occur within 1 second.

 