Front Panel Security Lockout (Executive mode)

Installation and Operation, cont’d

The Adjust knobs have no mechanical limits to their rotation.

Centering: Horizontal (Horz) adjusts horizontal positioning. Vertical (Vert) adjusts vertical positioning.

Sizing: Horizontal (Horz) adjusts horizontal sizing.

Vertical (Vert) adjusts vertical sizing.

Brightness/Contrast: Brightness adjusts from 0 to 63. Contrast adjusts from 0 to 255.

Color/Tint: Color adjusts from 0 to 127.

Tint adjusts from 0 to 255.

Zoom: Adjust zoom by observing the display and turning either adjustment knob either clockwise (zoom in) or counterclockwise (zoom out). The image increases/decreases in size both horizontally and vertically.

Detail: Detail adjusts image sharpness from 0 to 7.

The USP 405 times out to the default menu after 10 seconds.

4.Repeat steps 2 and 3 for each image adjustment to be made for that input.

The LCD display may show that an adjustment is “Not Available” in place of a number if that adjustment does not apply to the input’s video format. The following input types display “Not Available” during certain picture adjustments; all other input types have full picture adjustments:

Input 1 RGB: no color and no tint, anytime

Input 2 RGB, RGBcvS: no color or tint anytime; YUVi, YUVp, Betacam 50,

Betacam 60, composite (PAL), S-video (PAL) and HDTV: no tint (but there is color)

Input 3 composite (PAL): no tint (but there is color)

Input 4 S-video (PAL): no tint (but there is color)

Input 5 (SDI): no color, no tint, no detail

Front Panel Security Lockout (Executive mode)

To prevent accidental changes to settings, press the Size and Zoom buttons simultaneously for 2 seconds to enable the USP 405’s front panel security lockout (Executive mode). Executive mode locks all front panel functions except input selection and the Freeze button. The menu system still returns to the default cycle when 10 seconds have elapsed. The USP 405’s front panel and the IR 801 are both affected by Executive mode. When Executive mode is active, all functions and adjustments can still be made through RS-232 control. For details on RS-232 control, see chapter 3.

To disable the Executive mode, press the Size and Zoom buttons simultaneously for 2 seconds.

Default

Cycle

Press for

2 seconds simultaneously*

Default

Cycle

Press for

2 seconds simultaneously*

SIZE

 

ZOOM

 

 

 

Executive Mode

Enabled

10sec. timeout

*Executive mode can be enabled or disabled from any menu

10 sec. timeout

SIZE

 

ZOOM

 

 

 

Executive Mode

Disabled