Extron electronic USP 405 Serial Communication, cont’d, ASCII Command, Response, Pixel phase

Models: USP 405

1 64
Download 64 pages 32.04 Kb
Page 46
Image 46
ASCII Command

Serial Communication, cont’d

Command/response table for SIS commands (continued)

Command

ASCII Command

Response

Additional description

 

(host to USP)

(USP to host)

 

 

 

 

 

View the freeze status

F

Example:

F

X9

Show the freeze status.

0Response

Pixel phase

Set a specific pixel sampling phase

 

X1

*

X21

U

Example:

1*17U

Increment sampling value

 

 

+ U

 

X1

Decrement sampling value

 

 

- U

 

X1

View the sampling value

 

 

U

 

X1

X1 Phs X21

1Phs17 Show the freeze status.

X1 Phs X21

X1 Phs X21

X21

Specify the pixel sampling phase.

Set the sample phase to 17 for input 1.

Increase the phase value.

Decrease the phase value.

Show the pixel sampling phase.

Front panel security lockout (executive mode)

Disable

0X

Exe0

Adjustments & selections can

 

 

 

 

 

be made from the front panel.

Enable (lock image adjustments)

1X

Exe1

Lock front panel adjustments;

 

 

 

 

 

adjust image via RS-232 only.

 

 

 

 

 

 

View the executive mode status

X

 

X9

 

Show executive mode status.

Example:

X

0

 

Executive mode off.

 

 

 

 

 

 

Test pattern

Select test pattern

X12

J

Tst

Select test pattern

 

j

Tst

X12

View test pattern

J/j

 

 

Example:

J

 

 

X12

 

Select a test pattern.

 

 

Select a test pattern.

X12

 

 

 

Show the test pattern.

X12

 

0

Test pattern off.

Scaler output rate

Set the output rate

 

X7

*

 

X20

=

 

 

Rte

X7

*

 

X20

 

Select a global scaler output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

scan rate.

View the output rate

=

 

 

 

 

 

 

 

 

 

*

 

 

Show the global scaler output

 

 

 

 

 

 

 

 

X7

X20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

rate.

Set the output rate per input

 

 

 

 

 

*

 

=

Rte

 

*

 

 

Select a scaler output scan rate

 

X7

 

*

X20

X5

X7

X20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

for input

 

. An input of 0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X5

sets a global output rate for all inputs.

View the output rate per input

X5 =

X7 * X20

Show the scaler output rate. When input X5 = 0, the global output rate (prior to setting the rate using the per input command) is displayed.

Firmware version, part number & information requests

Query firmware version number

Q/q

x.xx

 

 

 

Show the controller firmware

 

 

 

 

 

 

 

 

 

version.

Request part number

N/n

xx-xxx-xx

 

 

 

Show the USP 405’s part #.

 

 

 

 

 

 

 

 

 

 

 

 

 

Request general info.

I/i

(See below)

 

 

 

Show the USP 405’s status.

 

 

Vid

X1

•Hrt

X15

•Vrt

X15

•Std

X16

•Pre

X19

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Zap (reset to default settings)

Zap all USP 405 settings

Esc

zXXX

ZpX

Reset everything: all settings,

 

 

 

and adjustments to the factory

 

 

 

default.

3-6 USP 405 • Serial Communication

Page 46
Image 46
Extron electronic USP 405 Serial Communication, cont’d, Command/response table for SIS commands continued, ASCII Command