Extron electronic USP 405 2Output menu, 3Memory Presets menu, 4Advanced Configuration menu, Menu

Models: USP 405

1 64
Download 64 pages 32.04 Kb
Page 5
Image 5
2Output menu

2Output menu

Input

Configuration

MENU

2

Output

Configuration

NEXT

Resol 1024 x 768

Refresh @ 60

NEXT

 

 

Output Signal

 

 

 

 

RGB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NEXT 3Memory Presets menu

Sync Polarity

H Neg

 

V Neg

 

 

 

NEXT

Scaler output rates

See the table in the "Output Configuration" section of chapter two for available combinations of resolutions and refresh rates.

Default: 640x480, 60 Hz

NOTE Lock = Accu-RATE Frame Lock™

Video types

Polarity combinations

RGB (default)

H-/V- (default)

H+/V-

Y, R-Y, B-Y

H-/V+

H+/V+

3Memory Presets menu

Output

Configuration

MENU

3

 

Memory

NEXT

Presets

 

Save Preset <N/A> 1 2 3

NEXT

 

 

Erase Preset

 

 

<N/A> 1 2 3

 

 

 

 

 

 

 

 

 

NEXT

Saving (Save) memory presets

Erasing (Erase) memory presets

Save the currently selected input's sizing and centering information.

Up to 3 presets per input can be

selected < > (N/A is the default) and saved.

Save a preset by pressing the Next button.

Erase the currently selected input's saved sizing and centering information.

Up to 3 presets per input can be selected < > (N/A is the default) and erased.

Erase a preset by pressing the Next button.

4Advanced Configuration menu

Output

Configuration

MENU

Advanced

Configuration

Either Adjust knob is used to adjust the submenus*

NEXT

Edge Smoothing

OFF <ON>

NEXT

Encoder Filter

06

NEXT

Blue Mode

<OFF> ON

NEXT

Test Pattern

Off

Smooth edges

On (default)

Off

Encoder filter setting

0 thru 12 (default is 6) to adjust sharpness

Display blue and sync only

On

Off (default)

Set test pattern type

• Off (default)

• Alt pixel

• Color Bars

• Film aspect 1.78

Top Blanking Bot

021 030

NEXT

RGB Delay

0.2Seconds

NEXT

Enhanced Mode

<OFF> ON

NEXT

Press and Hold FREEZE to Reset

Top and Bottom Blanking*

Top blanking ranges from 000 (default) to 237

Bottom blanking ranges 000 (default) to 237

RGB delay time

(in seconds)

0.0 to 5.0 seconds

in 0.1 sec. increments (0.7 second default)

Enhanced mode (gain control)*

On (default)

Off

To reset the scaler, press and hold the Freeze button until reset message displays

NOTE Adjust knobs do not affect

NEXT

• Crosshatch

• Film aspect 1.85

• 4 x 4 crosshatch

• Film aspect 2.35

• Grayscale

• Ramp

• Crop

 

NEXT

Input 2 PAL Film

<OFF> ON

NEXT

this submenu.

PAL Film Mode

On

Off (default)

*If the Test Pattern is set "On",
"Not Available" is displayed.

USP 405 • Quick Start QS-3

Page 5
Image 5
Extron electronic 2Output menu, 3Memory Presets menu, 4Advanced Configuration menu, USP 405 Quick Start QS-3, Menu