4.Configuring the FieldServer as a Metasys N2 Client

For a detailed discussion on FieldServer configuration, please refer to the FieldServer Configuration manual. The information that follows describes how to expand upon the factory defaults provided in the configuration files included with the FieldServer (See “.csv” sample files provided with the FieldServer).

This section documents and describes the parameters necessary for configuring the FieldServer to communicate with a Metasys N2 Server.

4.1.Data Arrays/Descriptors

The configuration file defines the FieldServer interfaces, and the data routing required. In order to enable the FieldServer for Metasys N2 communications, the driver independent FieldServer buffers need to be declared in the “Data Arrays” section, the destination device addresses need to be declared in the “Client Side Nodes” section, and the data required from the Servers needs to be mapped in the “Client Side Map Descriptors” section.

Note that in the tables, * indicates an optional parameter, with the bold legal value being the default value. Where only one legal value is given, no other values for that parameter are allowed.

Section Title

 

 

 

 

Data_Arrays

 

 

 

 

Column Title

Function

 

Legal Values

Data_Array_Name

Provide name for Data Array

 

Up to 15 alphanumeric

 

characters

 

 

 

 

 

 

Float, Bit, UInt16, SInt16,

Data_Array_Format

Provide data format. Each Data Array

Packed_Bit, Byte,

can only take on one format.

 

Packed_Byte,

 

 

 

 

 

Swapped_Byte

 

Number of Data Objects. Must be

 

 

 

Data_Array_Length

larger than the data storage area

 

1-10,000

 

required by the Map Descriptors for

 

 

 

 

 

 

 

the data being placed in this array.

 

 

 

 

 

 

 

 

Example

 

 

 

 

 

 

 

 

 

// Data Arrays

 

 

 

 

Data_Arrays

 

 

 

 

Data_Array_Name,

Data_Format,

Data_Array_Length

 

DA_AI_01,

UInt16,

200

 

DA_AO_01,

UInt16,

200

 

DA_DI_01,

Bit,

200

 

DA_DO_01,

Bit,

200

 